(800) 332 6615
[email protected]
CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660
CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660-2CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660-3CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660-4CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660-5CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660-6CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660-7CADD-PCA-5800-Ambulatory-Hand-Held-Portable-0-20mlhr-9v-Battery-Infusion-Pump-272446037660-8

CADD PCA 5800 Ambulatory Hand-Held Portable 0-20ml/hr 9v-Battery Infusion Pump

$159.99

1 in stock

Compare
SKU: 272446037660 Category:

Product Description

What You’ll get:

  • CADD PCA 5800 Ambulatory Hand-Held Portable 0-20ml/hr 9v-Battery Infusion Pump

Battery, Power Adapter are Not Included

Other Accessories that are Not pictured or mentioned under “What You’ll Get” are  Not  included

Please Visit our Web Store for more products www.eTechResale.com

Testing:

Unit will power ON but we do not have the correct accessories to fully test the unit. Therefore the unit is been
Sold AS-Is for parts or repair!

Cosmetics:

Pictures are of the actual unit. The front cover plate is missing and will not be included. There are visible scuffs and scratches. Please Reference pictures for cosmetics.

Taken from the Internet: 

The CADD PCA 5800 Ambulatory Infusion Pump has intravenous, subcutaneous, epidural space, subarachnoid space infusion applications. Designed to provide measured drug therapy, the CADD-PCA pump operates in continuous delivery mode, programmed automatic dose delivery, and demand dose delivery. Depending on the concentration, this ambulatory infusion pump has a continuous rate of 0-20 ml/hr or 0-99.5 mg/hr. Patient activated dose intervals range from 5-999 minutes in 1 minute increments.

Product Specifications

Pump Resolution:

50 microliters per interval

 

Dimensions:

1.1? D x 3.5? W x 6.4? H including 50 ml reservoir

 

Weight:

Approximately 1 pound including battery and empty 50 ml reservoir

 

Power Source:

9-volt alkaline or lithium battery

 

Pump Timing Accuracy:

±0.1%

 

System Delivery Accuracy:

±6% nominal

 

Continuous Rate:

0-20 ml/hr or 0-99.5 mg/hr, depending on concentration

 

Patient Activated Dose Intervals:

5 min – 999 min in 1 min increments

 

Patient Activated Doses per Hour:

0-12 over the last 60 minute period

 

Accumulated Delivery:

0-999 mg or ml, rounded down according to concentration setting

 

Number of Patient Activated Doses Delivered:

0-999

 

Number of Patient Activated Doses Attempted:

0-999

 

Reservoir Volume Range:

1-999 ml rounded up to the nearest ml in 1 ml increments

 

Given Range:

0-999 mg or ml

 

Clinician Activated Bolus:

0-20 ml or 0-99.5 mg, depending on concentration

 

Patient Activated Dose:

0-6 ml or 0-99.0 mg, depending on concentration

 

Pump Alarms:

Low battery

Battery Depleted

Pump in Stop Mode

Controller, microprocessor, or motor fault

Improper Delivery

Power Up Fault

Low Residual volume

RES VOL = 000

High Delivery Pressure (28 ± 12 psi)


 

Additional Information

Weight 2 lbs
Brand

CADD

Model

PCA 5800

MPN

PCA 5800

Not Included

Battery/ Power Adapter/Anything Else Not Mentioned

UPC

Does Not Apply